Online Support
Corporate/Bulk Orders Get Support from our B2B Sales Team
Contact

XPSBC3710

$745.95
Main Range of product Preventa Safety automation Product or component type Preventa safety module Safety module name XPSBC Safety module application For electrical monitoring of two-hand control stations Function of module Monitoring two-hand control station Safety level Can reach PL e/category 4 conforming to EN/ISO 13849-1 Safety reliability data MTTFd...
Main
Range of product Preventa Safety automation
Product or component type Preventa safety module
Safety module name XPSBC
Safety module application For electrical monitoring of two-hand control stations
Function of module Monitoring two-hand control station
Safety level Can reach PL e/category 4 conforming to EN/ISO 13849-1
Safety reliability data MTTFd = 63.9 years conforming to EN/ISO 13849-1
DC > 99 % conforming to EN/ISO 13849-1
PFHd = 1.75E-8 1/h conforming to EN/IEC 62061
Connections - terminals Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible without cable end
Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid without cable end
Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel
Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel
Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible without cable end
Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid without cable end
Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel
Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Output type Relay, 2 NO circuit(s), volt-free
Number of additional circuits 1 NC
[Us] rated supply voltage 230 V AC - 15...10 %
Complementary
Synchronisation time between inputs 0.5 s
Supply frequency 50/60 Hz
Maximum power consumption in VA 6 VA
Input protection type Internal, electronic
Number of inputs 1 NC + NO
Input voltage 30 V
Input current 50 mA
Input compatibility Two-hand control conforming to EN 574/ISO 13851-III C
[Uc] control circuit voltage 48 V DC
Breaking capacity 180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
Breaking capacity 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
[Ith] conventional free air thermal current 2.5 A
Associated fuse rating 4 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current 10 mA for relay output
Minimum output voltage 17 V for relay output
Maximum response time on input open 30 ms
[Ui] rated insulation voltage 300 V (pollution degree 2) conforming to IEC 60947-5-1
300 V (pollution degree 2) conforming to DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage 4 kV overvoltage category III conforming to IEC 60947-5-1
4 kV overvoltage category III conforming to DIN VDE 0110 part 1
Local signalling 3 LEDs
Mounting support 35 mm symmetrical DIN rail
Net weight 0.4 kg
Environment
Standards EN/IEC 60947-5-1
EN/IEC 60204-1
EN 574 type III C/ISO 13851
Product certifications UL
T√úV
CSA
IP degree of protection IP20 (terminals) conforming to EN/IEC 60529
IP40 (enclosure) conforming to EN/IEC 60529
Ambient air temperature for operation -10…55 °C
Ambient air temperature for storage -25…85 °C
Contractual warranty
Warranty 18 months
You have successfully subscribed!