XPSBC3110
$764.26
Main Range of product Preventa Safety automation Product or component type Preventa safety module Safety module name XPSBC Safety module application For electrical monitoring of two-hand control stations Function of module Monitoring two-hand control station Safety level Can reach PL e/category 4 conforming to EN/ISO 13849-1 Safety reliability data MTTFd...
Main
| Range of product | Preventa Safety automation |
| Product or component type | Preventa safety module |
| Safety module name | XPSBC |
| Safety module application | For electrical monitoring of two-hand control stations |
| Function of module | Monitoring two-hand control station |
| Safety level | Can reach PL e/category 4 conforming to EN/ISO 13849-1 |
| Safety reliability data | MTTFd = 63.9 years conforming to EN/ISO 13849-1 DC > 99 % conforming to EN/ISO 13849-1 PFHd = 1.75E-8 1/h conforming to EN/IEC 62061 |
| Connections - terminals | Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible without cable end Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid without cable end Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible without cable end Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid without cable end Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel |
| Output type | Relay, 2 NO circuit(s), volt-free |
| Number of additional circuits | 1 NC |
| [Us] rated supply voltage | 24 V AC - 15...10 % |
Complementary
| Synchronisation time between inputs | 0.5 s |
| Supply frequency | 50/60 Hz |
| Maximum power consumption in VA | 6 VA |
| Input protection type | Internal, electronic |
| Number of inputs | 1 NC + NO |
| Input voltage | 30 V |
| Input current | 50 mA |
| Input compatibility | Two-hand control conforming to EN 574/ISO 13851-III C |
| [Uc] control circuit voltage | 48 V DC |
| Breaking capacity | 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output |
| Breaking capacity | 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output |
| [Ith] conventional free air thermal current | 2.5 A |
| Associated fuse rating | 4 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
| Minimum output current | 10 mA for relay output |
| Minimum output voltage | 17 V for relay output |
| Maximum response time on input open | 30 ms |
| [Ui] rated insulation voltage | 300 V (pollution degree 2) conforming to IEC 60947-5-1 300 V (pollution degree 2) conforming to DIN VDE 0110 part 1 |
| [Uimp] rated impulse withstand voltage | 4 kV overvoltage category III conforming to IEC 60947-5-1 4 kV overvoltage category III conforming to DIN VDE 0110 part 1 |
| Local signalling | 3 LEDs |
| Mounting support | 35 mm symmetrical DIN rail |
| Net weight | 0.4 kg |
Environment
| Standards | EN/IEC 60204-1 EN 574 type III C/ISO 13851 EN/IEC 60947-5-1 |
| Product certifications | CSA UL T√úV |
| IP degree of protection | IP20 (terminals) conforming to EN/IEC 60529 IP40 (enclosure) conforming to EN/IEC 60529 |
| Ambient air temperature for operation | -10…55 °C |
| Ambient air temperature for storage | -25…85 °C |
Contractual warranty
| Warranty | 18 months |