XEND1621
$177.41
Main Range of product Harmony XAC Product or component type Contact block Component name XEND Electrical circuit type Control circuit Contact block application 2-speed Contact block type Double Type of operator 2 spring return Product compatibility XACB XACM Mechanical interlocking With mechanical interlocking Contacts type and composition 2 NO Mounting...
Main
| Range of product | Harmony XAC |
| Product or component type | Contact block |
| Component name | XEND |
| Electrical circuit type | Control circuit |
| Contact block application | 2-speed |
| Contact block type | Double |
| Type of operator | 2 spring return |
| Product compatibility | XACB XACM |
| Mechanical interlocking | With mechanical interlocking |
| Contacts type and composition | 2 NO |
| Mounting of block | Front mounting |
| Contact operation | Staggered Slow-break |
Complementary
| Connections - terminals | Screw clamp terminals, 1 x 2.5 mm² with or without cable end Screw clamp terminals, 2 x 1.5 mm² with or without cable end |
| Mechanical durability | 1000000 cycles |
| Contact code designation | A300 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A Q300 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A |
| [Ithe] conventional enclosed thermal current | 10 A |
| [Ui] rated insulation voltage | 400 V (pollution degree 3) conforming to IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 6 kV IEC 60947-1 |
| Maximum resistance across terminals | 25 MOhm |
| Short-circuit protection | 10 A fuse protection by cartridge fuse type gG |
| Rated operational power in W | 31 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 35 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 48 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C |
| Rated operational power in VA | 140 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 24 V 50/60 Hz, load factor = 0.5 (inductive load) 210 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 48 V 50/60 Hz, load factor = 0.5 (inductive load) 640 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 127 V 50/60 Hz, load factor = 0.5 (inductive load) 680 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 230 V 50/60 Hz, load factor = 0.5 (inductive load) |
| Terminals description ISO n°1 | (23-24)NO_CL B (13-14)NO |
| Terminals description ISO n°2 | (33-34)NO (43-44)NO_CL B |
| Terminal identifier | (11-12)NC (13-14)NO |
| Net weight | 0.11 kg |
Environment
| Standards | IEC 60947-5-1 EN 60947-5-1 CSA C22.2 No 14 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -40…70 °C |
| Vibration resistance | 15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 100 gn conforming to IEC 60068-2-27 |
Offer Sustainability
| REACh Regulation | REACh Declaration |
| REACh free of SVHC | Yes |
| EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration |
| Toxic heavy metal free | Yes |
| Mercury free | Yes |
| RoHS exemption information | Yes |
| China RoHS Regulation | China RoHS declaration |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Contractual warranty
| Warranty | 18 months |