Main Range of product Zelio Control Product or component type Modular measurement and control relays Relay type Pump control relays Product specific application For 3-phase and single-phase pump Relay name RM35BA Relay monitored parameters Overcurrent and undercurrent control Phase sequence on 3-phase supply Phase failure on 3-phase supply Time delay...
Main
| Range of product | Zelio Control |
| Product or component type | Modular measurement and control relays |
| Relay type | Pump control relays |
| Product specific application | For 3-phase and single-phase pump |
| Relay name | RM35BA |
| Relay monitored parameters | Overcurrent and undercurrent control Phase sequence on 3-phase supply Phase failure on 3-phase supply |
| Time delay type | Adjustable 1...60 s, +/- 10 % Ti on energisation Fixed 0.3 s reset on terminal Y2 Adjustable 0.1...10 s, +/- 10 % Tt on crossing the threshold |
| Switching capacity in VA | 1250 VA |
| Minimum switching current | 10 mA at 5 V DC |
| Maximum switching current | 5 A AC/DC |
| Maximum power consumption in VA | 5 VA AC |
| Measurement range | 1...10 A AC |
| Utilisation category | AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 |
Complementary
| Reset time | 2000 ms |
| Maximum switching voltage | 250 V AC/DC |
| [Un] rated nominal voltage | 208...480 V AC 3 phases 230 V AC single phase |
| [Un] rated nominal voltage | 208...480 V AC 3 phases 230 V AC 1 phase |
| Supply voltage limits | 183…528 V AC |
| Operating voltage tolerance | - 15 % + 10 % Un |
| Resistance across terminals | 0.01 Ohm at E1-L2 terminals |
| Width | 35 mm |
| Output contacts | 1 C/O |
| Nominal output current | 5 A |
| Maximum measuring cycle | 140 ms as true rms value |
| Delay at power up | 0.5 s |
| Hysteresis | 5 % of threshold |
| Measurement accuracy | +/- 10 % of the full scale value |
| Repeat accuracy | +/- 1 % for input and measurement circuit +/- 1 % for time delay |
| Measurement error | 1 % by volt over the whole range +/- 0.05 %/°C |
| Response time | < 300 ms (in the event of a fault) |
| Overload input current | 11 A permanent at 25 °C E1-L2 terminals 50 A non repetitive < 1 s at 25 °C E1-L2 terminals |
| Marking | CE : EMC 89/336/EEC CE : 73/23/EEC |
| Overvoltage category | III conforming to IEC 60664-1 |
| Insulation resistance | > 500 MOhm at 500 V DC between supply and relay output conforming to 60255-5 > 500 MOhm at 500 V DC between measurement and relay output conforming to 60664-1 > 1 MOhm at 500 V DC between supply and measurement conforming to 60255-5 > 500 MOhm at 500 V DC between supply and relay output conforming to 60664-1 > 500 MOhm at 500 V DC between measurement and relay output conforming to 60255-5 > 1 MOhm at 500 V DC between supply and measurement conforming to 60664-1 |
| [Ui] rated insulation voltage | 400 V conforming to IEC 60664-1 |
| Supply frequency | 50/60 Hz +/- 10 % |
| Operating position | Any position |
| Connections - terminals | Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end |
| Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
| Housing material | Self-extinguishing plastic |
| Status LED | 1 LED green for power ON 1 LED yellow for fault 1 LED yellow for relay ON |
| Mounting support | 35 mm symmetrical DIN rail conforming to EN/IEC 60715 |
| Electrical durability | 100000 cycles |
| Mechanical durability | 30000000 cycles |
| Operating rate | <= 360 operations/hour full load |
Environment
| Immunity to microbreaks | 500 ms |
| Electromagnetic compatibility | Emission standard for industrial environments conforming to EN/IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3 Immunity for industrial environments conforming to NF EN/IEC 61000-6-2 |
| Standards | EN/IEC 60255-6 |
| Product certifications | C-Tick CSA GOST UL GL |
| Ambient air temperature for storage | -40…70 °C |
| Ambient air temperature for operation | -20…50 °C |
| Relative humidity | 95 % at 55 °C conforming to IEC 60068-2-30 |
| Vibration resistance | 0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1 1 gn (f= 57.6…150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1 |
| Shock resistance | 15 gn for 11 ms conforming to IEC 60255-21-1 |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529 |
| Pollution degree | 3 conforming to IEC 60664-1 |
| Dielectric strength | 2 kV AC 50 Hz (shock wave 4 kV) |
Offer Sustainability
| Sustainable offer status | Green Premium product |
| REACh Regulation | REACh Declaration |
| EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration |
| Mercury free | Yes |
| RoHS exemption information | Yes |
| China RoHS Regulation | China RoHS declaration |
| Environmental Disclosure | Product Environmental Profile |
| Circularity Profile | End of Life Information |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Contractual warranty
| Warranty | 18 months |