XESD1181
$103.60
Main Range of product Harmony XAC Product or component type Contact block Component name XESD Electrical circuit type Control circuit Contact block application Single speed Contact block type Double Type of operator 2 spring return Product compatibility XACB XACM Mechanical interlocking With mechanical interlocking Mounting of block Front mounting Contact...
Main
| Range of product | Harmony XAC |
| Product or component type | Contact block |
| Component name | XESD |
| Electrical circuit type | Control circuit |
| Contact block application | Single speed |
| Contact block type | Double |
| Type of operator | 2 spring return |
| Product compatibility | XACB XACM |
| Mechanical interlocking | With mechanical interlocking |
| Mounting of block | Front mounting |
| Contact operation | Snap action |
Complementary
| Connections - terminals | Screw clamp terminals, 1 x 2.5 mm² with or without cable end Screw clamp terminals, 2 x 1.5 mm² with or without cable end |
| Mechanical durability | 1000000 cycles |
| Contact code designation | A300 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A Q300 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A |
| [Ithe] conventional enclosed thermal current | 10 A |
| [Ui] rated insulation voltage | 500 V (pollution degree 3) conforming to IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 6 kV IEC 60947-1 |
| Maximum resistance across terminals | 25 MOhm |
| Operating force | 15 N 25 N |
| Short-circuit protection | 10 A fuse protection by cartridge fuse type gG |
| Rated operational power in W | 140 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 140 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 95 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C |
| Rated operational power in VA | 100 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 48 V 50/60 Hz, load factor = 0.5 (inductive load) 450 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 127 V 50/60 Hz, load factor = 0.5 (inductive load) 50 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 24 V 50/60 Hz, load factor = 0.5 (inductive load) 750 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 230 V 50/60 Hz, load factor = 0.5 (inductive load) |
| Terminals description ISO n°1 | B (13-14-11-12)OF |
| Terminals description ISO n°2 | B (23-24-21-22)OF |
| Terminal identifier | (13-14)NO (11-12)NC |
Environment
| Standards | CSA C22.2 No 14 EN 60947-5-1 IEC 60947-5-1 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -40…70 °C |
| Vibration resistance | 15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 100 gn conforming to IEC 60068-2-27 |
| Electrical shock protection class | Class II conforming to IEC 61140 |
Offer Sustainability
| REACh Regulation | REACh Declaration |
| REACh free of SVHC | Yes |
| EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration |
| Toxic heavy metal free | Yes |
| Mercury free | Yes |
| RoHS exemption information | Yes |
| China RoHS Regulation | China RoHS declaration |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Contractual warranty
| Warranty | 18 months |