XCRT215
$776.14
Main Range of product OsiSense XC Series name Special format Product or component type Limit switch Product specific application For conveyor belt shift monitoring Device short name XCRT Sensor design - Body type Fixed Head type Rotary head Material Metal Fixing mode By the body Movement of operating head Rotary...
Main
| Range of product | OsiSense XC |
| Series name | Special format |
| Product or component type | Limit switch |
| Product specific application | For conveyor belt shift monitoring |
| Device short name | XCRT |
| Sensor design | - |
| Body type | Fixed |
| Head type | Rotary head |
| Material | Metal |
| Fixing mode | By the body |
| Movement of operating head | Rotary |
| Type of operator | Spring return roller stainless steel with lever |
| Type of approach | Lateral approach, 2 directions |
| Electrical connection | Screw-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm² |
| Number of poles | 2 |
| Contacts type and composition | 2 C/O |
| Contact operation | Snap action |
| Contact block per direction [control circuit] | 2 per direction |
| Positive opening | Without |
Complementary
| Body material | Zinc alloy |
| Switch actuation | By conveyor belt |
| Cable entry | 1 entry tapped for Pg 13.5 cable gland, cable outer diameter: 9…12 mm conforming to NF C 68-300 |
| Contacts insulation form | Za |
| Number of steps | 2 |
| Minimum torque for tripping | 1 N.m |
| Minimum actuation speed | 0.01 m/min |
| Tripping angle | 10 ° for fault signalling 18 ° for stopping of the conveyor belt |
| Maximum displacement angle | -90 ° 90 ° |
| Contact code designation | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A |
| [Ui] rated insulation voltage | 300 V conforming to UL 508 500 V (pollution degree 3) conforming to IEC 60947-1 500 V (pollution degree 3) conforming to VDE 0110 300 V conforming to CSA C22.2 No 14 |
| Maximum resistance across terminals | 25 MOhm conforming to IEC 60255-7 category 3 |
| [Uimp] rated impulse withstand voltage | 6 kV IEC 60664 6 kV IEC 60947-1 |
| Short-circuit protection | 10 A cartridge fuse, type gG |
| Electrical durability | 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
| Mechanical durability | 300000 cycles |
| Width | 85 mm |
| Height | 95 mm |
| Depth | 75 mm |
| Net weight | 1.155 kg |
| Terminals description ISO n°1 | (11-12)NC (13-14)NO |
Environment
| Shock resistance | 30 gn for 18 ms conforming to IEC 60068-2-27 |
| Vibration resistance | 9 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
| IP degree of protection | IP65 conforming to IEC 60529 |
| Overvoltage category | Class I conforming to IEC 61140 Class I conforming to NF C 20-030 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -40…70 °C |
| Protective treatment | TC |
| Standards | CSA C22.2 No 14 NF C 79-130 IEC 60947-5-1 IEC 60204-1 EN 60204-1 EN 60947-5-1 |
Offer Sustainability
| REACh Regulation | REACh Declaration |
| EU RoHS Directive | Not applicable, out of EU RoHS legal scope |
| Environmental Disclosure | Product Environmental Profile |
| Circularity Profile | No need of specific recycling operations |
Contractual warranty
| Warranty | 18 months |