XACS415
$39.51
Main Range of product Harmony XAC Product or component type Contact block Component name XACS Electrical circuit type Control circuit Contact block type Single Type of operator Spring return Product compatibility XACA ZA2B... head Mechanical interlocking Without mechanical interlock Contacts type and composition 1 NC + 1 NO Mounting of...
Main
| Range of product | Harmony XAC |
| Product or component type | Contact block |
| Component name | XACS |
| Electrical circuit type | Control circuit |
| Contact block type | Single |
| Type of operator | Spring return |
| Product compatibility | XACA ZA2B... head |
| Mechanical interlocking | Without mechanical interlock |
| Contacts type and composition | 1 NC + 1 NO |
| Mounting of block | Front mounting |
| Contact operation | Slow-break |
Complementary
| Connections - terminals | Screw clamp terminals, 1 x 2.5 mm² with or without cable end Screw clamp terminals, 2 x 1.5 mm² with or without cable end |
| Horizontal fixing centres | 40 mm |
| Vertical fixing centres | 30 mm |
| Mechanical durability | 1000000 cycles |
| Contact code designation | A300 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A Q300 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A |
| [Ithe] conventional enclosed thermal current | 10 A |
| [Ui] rated insulation voltage | 500 V (pollution degree 3) conforming to IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 6 kV IEC 60947-1 |
| Maximum resistance across terminals | 25 MOhm |
| Short-circuit protection | 10 A fuse protection by cartridge fuse type gG |
| Rated operational power in W | 42 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 45 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 60 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C |
| Rated operational power in VA | 140 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 24 V 50/60 Hz, load factor = 0.5 (inductive load) 385 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 48 V 50/60 Hz, load factor = 0.5 (inductive load) 455 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 230 V 50/60 Hz, load factor = 0.5 (inductive load) 525 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 127 V 50/60 Hz, load factor = 0.5 (inductive load) |
| Terminals description ISO n°1 | (23-24)NO (11-12)NC |
| Terminal identifier | (11-12)NC (13-14)NO |
| Net weight | 0.07 kg |
Environment
| Standards | CSA C22.2 No 14 IEC 60947-5-1 EN 60947-5-1 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -40…70 °C |
| Vibration resistance | 15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 100 gn conforming to IEC 60068-2-27 |
Offer Sustainability
| REACh Regulation | REACh Declaration |
| REACh free of SVHC | Yes |
| EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration |
| Toxic heavy metal free | Yes |
| Mercury free | Yes |
| RoHS exemption information | Yes |
| China RoHS Regulation | China RoHS declaration |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Contractual warranty
| Warranty | 18 months |