STBART0200K

$539.72
Main Range of product Modicon STB distributed I/O solution Product or component type Standard analog input kit Kit composition STBART0200 module STBXTS1100, 6-terminal screw type connector STBXBA1000 base STBXTS2100, 6-terminal spring clamp connector Analogue input type Voltage +/- 80 mV Temperature probe -100...+260 °C Cu 10 2, 3 or 4...
Main
Range of product Modicon STB distributed I/O solution
Product or component type Standard analog input kit
Kit composition STBART0200 module
STBXTS1100, 6-terminal screw type connector
STBXBA1000 base
STBXTS2100, 6-terminal spring clamp connector
Analogue input type Voltage +/- 80 mV
Temperature probe -100...+260 °C Cu 10 2, 3 or 4 wires IEC
Temperature probe -100...+450 °C Pt 100 2, 3 or 4 wires US/JIS
Temperature probe -100...+450 °C Pt 1000 2, 3 or 4 wires US/JIS
Temperature probe -200...+850 °C Pt 100 2, 3 or 4 wires IEC
Temperature probe -200...+850 °C Pt 1000 2, 3 or 4 wires IEC
Temperature probe -60...+180 °C Ni 100 2, 3 or 4 wires IEC
Temperature probe -60...+180 °C Ni 1000 2, 3 or 4 wires IEC
Thermocouple +130...+1820 °C thermocouple B
Thermocouple -200...+760 °C thermocouple J
Thermocouple -270...+1000 °C thermocouple E
Thermocouple -270...+1370 °C thermocouple K
Thermocouple -270...+400 °C thermocouple T
Thermocouple -50...+1665 °C thermocouple R
Thermocouple -50...+1665 °C thermocouple S
Analogue input number 2
Analogue input resolution 15 bits + sign
Type of filter Single low pass input filter 25 Hz
Complementary
Absolute maximum input +/- 7.5 V DC
Cold swapping Yes
Hot swapping fallback Yes for standard NIMs
Fallback status State 0 basic NIMs
User configurable standard NIMs
Data format EN 61131-2
IEC 61131-2
Input impedance 10 MOhm +/- 80 mV
Maximum supply current for sensors 100 mA per input channels
Protection type Short-circuit protection
Absolute accuracy error +/- 0.1 % of full scale 25 °C internal
+/- 0.15 % of full scale 25 °C external
Insulation between channels and logic bus 1500 V for 1 minute
Addressing requirement 1 word for cold-junction compensation
2 input words
Product compatibility Mounting base STBXBA1000
Power distribution module STBPDT3100/3105
[Us] rated supply voltage 24 V DC
Supply Power distribution module
Current consumption 30 mA at 5 V DC for logic bus
Measurement resolution 0.01 mV voltage
0.1 °C or 0.1 °F temperature probe
0.1 °C or 0.1 °F thermocouple
Conversion time 150 ms voltage 60 Hz
170 ms voltage 50 Hz
180 ms temperature probe 60 Hz 2 or 4 wires
200 ms temperature probe 50 Hz 2 or 4 wires
210 ms thermocouple with internal cold-junction compensation 60 Hz
230 ms thermocouple with internal cold-junction compensation 50 Hz
300 ms temperature probe 60 Hz 3 wires
340 ms temperature probe 50 Hz 3 wires
360 ms thermocouple with external cold-junction compensation 60 Hz
400 ms thermocouple with external cold-junction compensation 50 Hz
Maximum wiring resistance 20 Ohm Cu 10 IEC/US/JIS 2 or 3 wires
20 Ohm Ni 100 IEC/US/JIS 2 or 3 wires
20 Ohm Pt 100 IEC/US/JIS 2 or 3 wires
200 Ohm Ni 1000 IEC/US/JIS 2 or 3 wires
200 Ohm Pt 1000 IEC/US/JIS 2 or 3 wires
50 Ohm Cu 10 IEC/US/JIS 4 wires
50 Ohm Ni 100 IEC/US/JIS 4 wires
50 Ohm Pt 100 IEC/US/JIS 4 wires
500 Ohm Ni 1000 IEC/US/JIS 4 wires
500 Ohm Pt 1000 IEC/US/JIS 4 wires
Measurement accuracy +/- 1 °C Ni 100 25 °C external
+/- 1 °C Ni 100 25 °C internal
+/- 1 °C Ni 1000 25 °C external
+/- 1 °C Ni 1000 25 °C internal
+/- 1 °C Pt 100 25 °C internal
+/- 1 °C Pt 1000 25 °C internal
+/- 1.75 °C thermocouple B with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple E with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple J with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple K with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple R with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple S with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple T with external cold-junction compensation 25 °C
+/- 2 °C Pt 100 25 °C external
+/- 2 °C Pt 1000 25 °C external
+/- 2.85 °C thermocouple B with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple E with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple J with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple K with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple R with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple S with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple T with external cold-junction compensation 60 °C
+/- 3.6 °C thermocouple R with internal cold-junction compensation 25 °C
+/- 4 °C Cu 10 25 °C external
+/- 4 °C Cu 10 25 °C internal
+/- 4 °C thermocouple K with internal cold-junction compensation 25 °C
+/- 4.1 °C thermocouple S with internal cold-junction compensation 25 °C
+/- 4.2 °C thermocouple R with internal cold-junction compensation 60 °C
+/- 4.4 °C thermocouple T with internal cold-junction compensation 25 °C
+/- 4.6 °C thermocouple B with internal cold-junction compensation 25 °C
+/- 4.6 °C thermocouple E with internal cold-junction compensation 25 °C
+/- 5 °C thermocouple S with internal cold-junction compensation 60 °C
+/- 5.1 °C thermocouple J with internal cold-junction compensation 25 °C
+/- 5.5 °C thermocouple K with internal cold-junction compensation 60 °C
+/- 6.4 °C thermocouple T with internal cold-junction compensation 60 °C
+/- 6.8 °C thermocouple B with internal cold-junction compensation 60 °C
+/- 6.8 °C thermocouple E with internal cold-junction compensation 60 °C
+/- 7 °C thermocouple J with internal cold-junction compensation 60 °C
Marking CE
Overvoltage category II
Status LED 1 LED (green)module status (RDY):
1 LED (red)module error (ERR):
Environment
Product certifications UL
FM Class 1 Division 2
CSA
ATEX Cat 3G
C-Tick
Pollution degree 2 conforming to IEC 60664-1
Operating altitude <= 2000 m
IP degree of protection IP20 conforming to EN 61131-2 class 1
Ambient air temperature for operation 0…70 °C
Ambient air temperature for operation 32...140 °F without
Ambient air temperature for storage -40…85 °C without
Ambient air temperature for storage -40...185 °F without
Relative humidity 95 % at 60 °C without condensation
Vibration resistance +/-0.35 mm at 10…58 Hz
3 gn at 58…150 Hz on 35 x 7.5 mm symmetrical DIN rail
5 gn at 58…150 Hz on 35 x 15 mm symmetrical DIN rail
Shock resistance 30 gn for 11 ms conforming to IEC 88 reference 2-27
Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
REACh Declaration
EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End of Life Information
WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Contractual warranty
Warranty 18 months
You have successfully subscribed!
This email has been registered
ico-collapse
0
Recently Viewed
Top
ic-expand
ic-cross-line-top