Online Support
Corporate/Bulk Orders Get Support from our B2B Sales Team
Contact

RM35ATW5MW

$319.09
Main Range of product Zelio Control Product or component type Modular measurement and control relays Relay type Temperature control relays Product specific application For elevator machine rooms and 3-phase supplies Relay name RM35AT Relay monitored parameters Phase sequence Phase failure detection Undertemperature: -1...11°C Overtemperature: 34...46°C Time delay range 0.1...10 s...
Main
Range of product Zelio Control
Product or component type Modular measurement and control relays
Relay type Temperature control relays
Product specific application For elevator machine rooms and 3-phase supplies
Relay name RM35AT
Relay monitored parameters Phase sequence
Phase failure detection
Undertemperature: -1...11°C
Overtemperature: 34...46°C
Time delay range 0.1...10 s adjustable delay (tolerance: 0...10 % of the full scale value)
Switching capacity in VA 1250 VA
Minimum switching current 10 mA at 5 V DC
Maximum power consumption in VA 3.5 VA AC
Utilisation category AC-12 conforming to IEC 60947-5-1
AC-13 conforming to IEC 60947-5-1
AC-14 conforming to IEC 60947-5-1
AC-15 conforming to IEC 60947-5-1
DC-12 conforming to IEC 60947-5-1
DC-13 conforming to IEC 60947-5-1
DC-14 conforming to IEC 60947-5-1
Complementary
Reset time 8 s
Maximum switching voltage 250 V AC/DC
[Us] rated supply voltage 24...240 V AC/DC
[Us] rated supply voltage 24...240 V AC/DC
Supply voltage limits 20.4…264 V AC
21.6…264 V DC
Maximum power consumption in W 0.6 W DC
Resistance across terminals 600 kOhm at 3-phase
1.33 kOhm at temperature
Width 35 mm
Output contacts 2 NO
Contacts material Cadmium free
Nominal output current 5 A
Delay at power up 0.2 s
Measurement accuracy +/- 2 °C
Response time <= 3.5 s + Tt (in case of temperature fault)
500 ms (in case of 3-phase fault)
500 ms (on disappearance of fault)
Temperature probe type Pt 100 - 3-wire
Installed device Pt 100 probe cable length <= 10 m
Marking CE : EMC 89/336/EEC
CE : 73/23/EEC
Overvoltage category III conforming to IEC 60664-1
Insulation resistance > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5
> 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1
> 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5
> 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1
> 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5
> 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1
[Ui] rated insulation voltage 400 V conforming to IEC 60664-1
Operating voltage tolerance - 10 % + 10 % Un DC
- 15 % + 10 % Un AC
Supply frequency 50/60 Hz +/- 10 %
Operating position Any position without
Connections - terminals Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
Tightening torque 0.6…1 N.m conforming to IEC 60947-1
Housing material Self-extinguishing plastic
Local signalling 1 LED green for power ON
1 LED yellow for correct temperature (high R1)/(low R2)
1 LED yellow for phases of relay
Mounting support 35 mm symmetrical DIN rail conforming to EN/IEC 60715
Electrical durability 100000 cycles
Mechanical durability 30000000 cycles
Operating rate <= 360 operations/hour full load
Environment
Immunity to microbreaks 10 ms
Electromagnetic compatibility Emission standard for industrial environments conforming to EN/IEC 61000-6-4
Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3
Immunity for industrial environments conforming to NF EN/IEC 61000-6-2
Standards NF EN 60255-6
IEC 60255-6
Product certifications GL
UL
C-Tick
CSA
GOST
Ambient air temperature for storage -40…70 °C
Ambient air temperature for operation -20…50 °C
Vibration resistance 0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1
1 gn (f= 57.6…150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1
Shock resistance 15 gn for 11 ms conforming to IEC 60255-21-1
IP degree of protection IP20 (terminals) conforming to IEC 60529
IP30 (casing) conforming to IEC 60529
Pollution degree 3 conforming to IEC 60664-1
Dielectric test voltage 2 kV, 1 min AC 50 Hz
Non-dissipating shock wave 4 kV
Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
REACh Declaration
EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End of Life Information
WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Contractual warranty
Warranty 18 months
You have successfully subscribed!
This email has been registered
ico-collapse
0
Recently Viewed
Top
ic-expand
ic-cross-line-top